¡Indeflator PS-25
Performance:
Maximum allowable pressure |
30 atm(441psi) |
Maximum chargeable liquid volume |
25 ml |
Pressure gauge precision |
}3%F.S. |
|
|
|
- Pressure gauge scale mark: Light-storing type. When lighted for 3~4 minutes, the scale marks gleam and can be seen clearly for 10~15 minutes after complete extinction.
- The initial charged liquid amount inside the syringe has been minimized.
- The minimum liquid volume to be charged for pressurization up to 30 atm has been displayed.
- Since the maximum chargeable liquid volume is 25 mL, there is room in negative-pressure volume at the time of deflation.
- Since the release button for inflation/deflation is located at the center, handling is possible with either the right or left hand.
- The release button is easy to handle.
|
|
|
|
|
¡Y-Adaptor(RackorV)
Performance:
Minimum inside diameter |
8F(2.7mm) |
Maximum diameter of tube inserted |
7.6F(2.5mm) |
Maximum allowable leakage pressure on inserting
PTCA catheter and guide wire |
1.2MPa (12.23Kg/c‡u) |
- The valve to stop bleeding is opened or closed by a lever system and easy to handle.
- When the handle lever is turned clockwise to the limit with the thumb, the lever will be locked, and the valve to stop bleeding will be in the fully-opened state.
- When the handle lever is turned anticlockwise with the thumb, the lever will turn automatically, and the valve to stop bleeding will be in the fully-closed state.
|
|
|
|
¡Y-Adaptor(Rackor W)
Performance:
Minimum inside diameter |
9F(3.0mm) |
Maximum diameter of tube inserted |
8.7F(2.9mm) |
Maximum allowable leakage pressure on
inserting PTCA catheter and guide wire
(but in the non-loaded state) |
1.2MPa (12.23Kg/c‡u) |
- When the handle lever is turned clockwise to the locked state, the valve to stop bleeding will be in the fully-opened state.
- When the handle lever is turned anticlockwise, the valve to stop bleeding will be in the fully-closed state, and the guide wire and other devices inserted at the same time into this product will show favorable retention.
- When the handle lever is pushed anticlockwise with the thumb, the handle will be in the locked state.
- The side port tube can be selected in the range of 200mm - 600mm.
|
|
|
¡Torquer
- Applicable guide wire: 0.009" - 0.018"
|
|
|
|
¡Insertor CI05
- Maximum applicable guide wire: 0.018"
|
|
|
|
¡Y adapter-set product
Model No. |
Component |
Product code |
CYV1 |
Y adapter (attached with pressure-resistant tube) |
4571174000814 |
CYVS1 |
Y adapter (attached with pressure-resistant tube)
Torquer
Inserter |
4571174000821 |
|
|
|
|
|
ypage topz |
|
|
|
Copyright(c)CENTRAL MFG.CO.,LTD.All